3.4.5.2 Suggested external wiring of Misc I/O card output
The circuit below shows suggested wiring for Output 1 of the 500-10-00 Misc I/O logic card.
Maximum current through the output stage must be limited to 200mA and the maximum
permitted external voltage is +200V. If these limits are exceeded, the card may be damaged.
Connector pin-out is shown in detail on page 24.